Product Selection

Co-Extruded Neon Flex vs Rigid Linear Profiles

Co-extruded neon flex vs rigid linear profiles: 6×6 to 20×20 mm sections, 120° emitting angle, 6063 aluminium housings and joint sealing.

GDXC Project Engineering · Published November 20, 2026 · 6 min read

Short answer

Co-extruded neon flex and rigid linear profiles are alternative constructions for a continuous line of architectural light. Neon flex is a co-extruded flexible strip with sections from 6×6 mm to 20×20 mm, a 120° emitting angle and documented weights of 43.5 / 57 / 109 g/m. Rigid profiles use extruded 6063 aluminium with 4 mm silk-screen round-hole glass on relevant models and follow straight runs.

Key points

  • The co-extruded flexible file holds 53 items: 48 neon flex strips, 2 wall-washer strips and 3 ultra-thin rigid bars.
  • Flexible sections run from 6×6 mm to 20×20 mm with a 120° emitting angle and weights of 43.5 / 57 / 109 g/m.
  • Rigid profiles use 6063 aluminium with 4 mm silk-screen round-hole glass and follow straight runs only.
  • IP65 covers most outdoor models and IP68 applies to underwater items; strip joint sealing is installation work.

Short answer

Co-extruded neon flex and rigid linear profiles are alternative constructions for a continuous line of architectural light. Neon flex is a co-extruded flexible strip with sections from 6×6 mm to 20×20 mm, a 120° emitting angle and documented weights of 43.5 / 57 / 109 g/m. Rigid profiles use extruded 6063 aluminium with 4 mm silk-screen round-hole glass on relevant models and follow straight runs.

Two documented constructions

A continuous line of light can be built from a flexible co-extruded strip or from an extruded rigid profile. They are documented in separate files, and they differ in geometry, sealing behaviour and what they can follow on a building. GDXC was established in 2014 and its scope covers outdoor architectural and landscape LED lighting plus DMX512 intelligent control.

AttributeCo-extruded neon flexRigid linear profile
ConstructionCo-extruded flexible stripExtruded 6063 aluminium profile
Section6×6 mm to 20×20 mmRigid housing, per model
Emitting angle120°Set by fitted optic
Documented weight43.5 / 57 / 109 g/mPer model
Optical windowDiffused co-extrusion4 mm silk-screen round-hole glass on relevant models
Curved outlinesUsed where the outline curvesStraight runs only
Source file53-item co-extruded flexible file5 product catalogues, 98 model entries

The section and weight figures apply to the strip itself; the 6063 aluminium housing carries both the heat path and the sealing geometry. That is why the choice is not only about bending: it changes how the run is fixed, how heat leaves the fixture and where the joints are made.

The co-extruded flexible file

The flexible range is documented separately from the rigid catalogues. Its 53 items break down as follows.

Item typeCount
Neon flex strips48
Wall-washer strips2
Ultra-thin rigid bars3
Total53

The 5 product catalogues with 98 model entries are a different document: 10 architectural linear lights, 20 wall washers, 29 floodlights, 12 in-ground and underwater lights, and 27 pixel point lights. A BOM that mixes a rigid wall washer with a curved neon flex outline must reference both documents; assuming the flexible items sit inside the 98 catalogue entries is a common submittal error. Flexible linear lighting is the page for the strip families, and architectural linear lights is the page for rigid linear runs.

Rigid dimensions and power classes

Rigid housings have documented dimensions and discrete power classes. The GD-WW3524 is W35 × H24 × L1002 mm at 18/24 W, the GD-WW4025 is W40 × H25 × L1003 mm at 24/36 W, and the GD-WW6036 is W60 × H36 × L1000 mm at 48/72 W.

ModelW × H × L (mm)Power (W)BOM note
GD-WW3524W35 × H24 × L100218 / 24Discrete driver and thermal design
GD-WW4025W40 × H25 × L100324 / 36Discrete driver and thermal design
GD-WW6036W60 × H36 × L100048 / 72Discrete driver and thermal design

Common lengths of 1000 / 500 / 260 mm set the joint pattern on a straight run, and a 24/36 W unit is not a dimmed 48/72 W unit. Thermal and materials covers the housing review that precedes selection, and how to specify linear LED light for building outlines covers the outline specification.

Optics, ingress and electrical lines

Neither construction changes the electrical, colour or control options. These are independent BOM lines, and they apply across the range.

LineDocumented optionsApplies to
Beam angle10°, 15°, 30°, 45°, 60°, 10×30°, 10×45°, 10×60°, 20×60°Rigid profiles with fitted optics
Emitting angle120°Co-extruded flexible strip
SupplyDC24V most low-voltage models; AC220V some floodlightsBoth
ColourSingle-colour 1800–6500K, RGB, RGBWBoth
ControlON/OFF, TTL, DMX512Both, fixed at order stage
IngressIP65 most outdoor models; IP68 underwater itemsBoth, per model

Pixel point lights are documented at 36/64/100/144/256/400 points per square metre, a density figure that affects control capacity but is a layout decision made by the client’s designer. An ON/OFF unit cannot be re-addressed as DMX512 after installation, so the control line must be fixed before the BOM is released. IP65 vs IP66 vs IP68 for outdoor lighting sets out the rating comparison, and IP66 is not a published default.

Joints, sealing and hot climates

The most important practical difference between the two constructions is where the sealing risk sits. On a rigid 6063 aluminium profile the glass-to-housing joint and the cable gland are factory-defined; on a flexible run the end caps and site-made joints are installation work. Outdoor waterproofing covers the sealing review.

ElementCo-extruded neon flexRigid linear profile
End capsSite-made, affect achieved ingress ratingFactory-defined housing ends
Site-made jointsPresent on curved runsPresent between 1000 / 500 / 260 mm units
Glass-to-housing jointNot applicable4 mm silk-screen round-hole glass on relevant models
Heat pathCo-extruded section6063 aluminium profile
Hot-climate concernJoint cycling and end-cap integrityGasket and glass joint cycling

Why LED facade fixtures fail in hot climates explains the cycling mechanism, and facade lighting BOM checklist for contractors covers the line-by-line submittal. Catalogues state 50,000 hours for the source, a catalogue-stated figure, not a warranty commitment.

Documentation and commercial handling

The compliance wording available is: “CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model.” No certification number, fixed lead time, published price or warranty period is provided, and the 50,000 hours figure is a catalogue-stated figure, not a warranty commitment. GDXC is based in Guangming District, Shenzhen, Guangdong Province, China, prioritises the Middle East and Southeast Asia, and also covers Europe, North America, South America and Africa. Enquiries: chenliang@gdzm-led.com, +86 153 0264 9886, WhatsApp 8615302649886.

What we do not cover / Limits

This article compares co-extruded flexible strip and rigid extruded profiles for exterior architectural and landscape lighting only. It does not apply to indoor residential lighting or to road and tunnel main lighting, which are outside GDXC’s scope. GDXC does not sell LED chips, packages or bare light sources and does not publish client drawings. No bend radius, cut length, fixing spacing, joint detail, voltage-drop calculation or illuminance target is provided here; those must be produced by the client’s engineering personnel from the project drawings. The article does not cover submerged installations using non-IP68 models, AC220V mains floodlighting design, or curved runs built from rigid 6063 aluminium profiles. We do not promise unverified certifications, fixed lead times or published prices, and no warranty period is offered; the 50,000 hours figure is a catalogue-stated figure, not a warranty commitment. Final fixture selection, quotation and installation work must be confirmed by the client’s own engineering team.

This article describes general practice in outdoor architectural LED lighting. It is not a substitute for a project-specific review — beam angle, IP rating and control mode must be confirmed against the fixture schedule, the elevation and the site conditions.

Questions

Frequently asked

What is the difference between co-extruded neon flex and rigid linear profiles?

Neon flex is a co-extruded flexible strip that follows curves, with sections from 6×6 mm to 20×20 mm and a 120° emitting angle; rigid profiles are extruded 6063 aluminium housings for straight runs. They are documented in separate files. Choose from the outline geometry on the drawing.

Can co-extruded neon flex be used outdoors?

IP65 is documented for most outdoor models and IP68 for underwater items, but the achieved rating of a strip run depends on end caps, joints and cable entries. Flexible sections are documented at 6×6 mm to 20×20 mm with weights of 43.5 / 57 / 109 g/m. Confirm the per-model IP test report and the joint detail.

How many co-extruded flexible items does GDXC document?

The co-extruded flexible file holds 53 items: 48 neon flex strips, 2 wall-washer strips and 3 ultra-thin rigid bars. It is separate from the 5 product catalogues with 98 model entries. A BOM that mixes rigid and flexible lines must reference both documents.

Which one should I use for a curved building outline?

Use co-extruded neon flex, because rigid 6063 aluminium profiles follow straight runs only. The flexible sections run from 6×6 mm to 20×20 mm with a 120° emitting angle. Final bend radii and fixing details must be confirmed by the client's engineering team.

Send your facade drawings or lighting effect renders

Share an elevation drawing, an effect render or a draft fixture list. Our project engineers return a fixture BOM, beam-angle and optical distribution suggestions, and DMX512 addressing coordination. Final selection, quotation and installation are confirmed with your technical team.

Chat on WhatsApp