Facade Lighting Selection and Optical Distribution Support
Project-based fixture selection and beam angle support for building facades: 98 catalogued models, 10-60 degree and elliptical optics, DC24V and DMX512.
Facade lighting selection is the process of matching fixture beam angle, wattage, mounting setback and colour to a measured building elevation before a BOM is issued. Guangdi Xingcan supports this from elevation drawings, effect renders and site photos across 98 catalogued fixture models, using 10, 15, 30, 45, 60 degree and elliptical 10x30, 10x45, 10x60, 20x60 degree optics at DC24V.
When this applies
This service covers fixture selection, beam and uniformity reasoning, and the technical questions a contractor must answer before ordering. It does not replace a licensed lighting designer, a photometric calculation sealed by the client engineer, structural fixing design, or a construction drawing set.
Technical specifications
| Catalogue basis | 98 fixture models across 5 product families in the 2026 catalogues |
|---|---|
| Beam options | 10, 15, 30, 45, 60 degrees; 10x30, 10x45, 10x60, 20x60 degree elliptical |
| Power options | 18 / 24 / 36 / 48 / 72 W on catalogued wall washer models |
| Standard lengths | 1000 / 500 / 260 mm; 995-1003 mm by model |
| Supply | DC24V on low-voltage families; AC220V on selected floodlights |
| Colour | Single colour 1800-6500 K, RGB, RGBW |
| Control | ON/OFF, TTL, DMX512 (model dependent) |
| Input from client | Elevation drawing, effect render, site photo, setback and budget range |
Where it is the right choice
- Building facades where wall height and mounting setback are known
- Hotel, commercial and bridge elevations with a defined night effect
- Projects that need a fixture schedule before tender pricing
- Middle East and Southeast Asia projects with high-temperature or coastal exposure
- Multi-product schemes combining wall washers, linear lights and floodlights
Where it is the wrong choice
Stating this explicitly matters more than a capability list: if your project falls into one of these categories, a different fixture family or a separate specialist review is the right answer.
- Sports field lighting, road lighting and tunnel lighting, which follow different standards
- Interior residential and retail fit-out lighting
- Projects with no elevation drawing, no setback dimension and no target effect
- Cases requiring a sealed photometric calculation, structural fixing design or statutory submission, which remain with the client designer
- Requests to name a single "best" fixture without surface reflectance and viewing distance
Documents and tools used
- 2026 architectural wall washer, linear, floodlight, in-ground and pixel catalogues
- Elevation drawings and effect renders supplied by the client
- Beam angle and setback comparison tables
- Project BOM template recording model, wattage, beam, colour, control and quantity
- Batch grouping notes for colour temperature consistency
Project questions
What information do you need before recommending a wall washer?
At minimum: the elevation height, the available mounting setback, the surface material and colour, the target effect photo, the supply voltage and the control requirement. Without the setback and surface, a 30 degree and a 10x60 degree beam cannot be compared meaningfully.
Do you produce the photometric calculation for the project?
No. We support selection from catalogue beam data and flag where uniformity will fail, but the sealed photometric calculation, glare assessment and statutory submission remain with the client lighting designer or engineer.
Can you work from a hand sketch or a phone photo?
Yes for an initial product-family shortlist. A priced BOM still needs the elevation dimensions and a confirmed setback, because those fix the beam angle and the number of rows.
Related capabilities and products
DMX512 Control & Addressing
DMX512 is a unidirectional digital control protocol that assigns each luminaire or pixel a channel range within a 512-channel universe. Guangdi Xingcan coordinates addressing, channel budgets and control topology for RGB and RGBW architectural fixtures, including pixel node densities from 36 to 400 points per square metre, and lists ON/OFF and TTL variants separately where dynamic control is not required..
View capabilityProject BOM & Quality Checks
A project BOM for architectural lighting is a fixture schedule that fixes model, wattage, beam angle, colour, control mode, length, IP rating and quantity for every installation zone before pricing. Guangdi Xingcan prepares BOMs from elevation drawings across 98 catalogued fixture models and 53 co-extruded profiles, groups fixtures by production batch for colour consistency, and powers every unit for a function check before packing..
View capabilityKnowledge Base
Beam angle, IP rating, DMX512 and photometric guides written for project buyers and contractors.
Read articlesSend your facade drawings or lighting effect renders
Share an elevation drawing, an effect render or a draft fixture list. Our project engineers return a fixture BOM, beam-angle and optical distribution suggestions, and DMX512 addressing coordination. Final selection, quotation and installation are confirmed with your technical team.