RGB vs RGBW vs Single Colour for Facades
RGB vs RGBW vs single colour for facades: what each colour system changes, how 1800–6500K compares, and which control protocol fits.
GDXC Project Engineering · Published October 26, 2026 · 6 min read
Single-colour, RGB and RGBW are the documented colour systems for outdoor architectural luminaires. Single-colour covers 1800–6500K white with a fixed output; RGB mixes red, green and blue channels for colour scenes; RGBW adds a dedicated white channel to RGB. Most low-voltage models run on DC24V, and the colour system and control protocol are separate BOM lines.
Key points
- Single-colour is documented at 1800–6500K; RGB mixes three channels and RGBW adds a dedicated white channel.
- Colour system and control protocol are separate BOM lines; ON/OFF, TTL and DMX512 are the documented control options.
- The same 6063 aluminium housing can be ordered as single-colour ON/OFF or RGBW DMX512.
- IP65 covers most outdoor models and IP68 applies to underwater items, regardless of colour system.
Short answer
Single-colour, RGB and RGBW are the documented colour systems for outdoor architectural luminaires. Single-colour covers 1800–6500K white with a fixed output; RGB mixes red, green and blue channels for colour scenes; RGBW adds a dedicated white channel to RGB. Most low-voltage models run on DC24V, and the colour system and control protocol are separate BOM lines.
What each colour system changes
Colour system describes the emitters inside the fixture, not its brightness or its housing. GDXC documents single-colour, RGB and RGBW across its outdoor architectural and landscape LED lighting range, which has been the company’s scope since it was established in 2014.
| Colour system | Emitters | What it produces | Constraint |
|---|---|---|---|
| Single-colour | One white channel | Fixed white output | Exact value confirmed per model |
| RGB | Red, green, blue channels | Mixed colour scenes | No dedicated white channel |
| RGBW | RGB plus a dedicated white channel | Colour scenes plus white | White channel needs its own control channel |
The practical difference shows up in white light. RGB produces white by mixing channels; RGBW has a separate white emitter, which is why it is specified for schemes that switch between saturated colour and a white state. Both are options on the same 6063 aluminium housing, so the body, the 4 mm silk-screen round-hole glass on relevant models, and the IP65 or IP68 rating do not change with the colour system.
The white range and the colour systems
Single-colour is documented across 1800–6500K. The range is a span, not a list of stocked values, so a submittal should name the exact value rather than writing the range into a part number.
| Line | Documented value | How to specify it |
|---|---|---|
| Single-colour white | 1800–6500K | Name the exact value per model |
| RGB | Three mixed channels | Not a white-temperature option |
| RGBW | RGB plus white channel | Not a white-temperature option |
| Supply | DC24V most low-voltage models; AC220V some floodlights | Separate BOM line |
| Ingress | IP65 most outdoor models; IP68 underwater items | Separate BOM line |
RGB and RGBW are not points on the 1800–6500K range; they are channel architectures. Treating a combined colour-system and white-temperature label as a single valid line item is a common submittal error, and no intermediate white-temperature value is published here. The client’s designer sets the colour intent, and the exact emitter configuration is confirmed per model.
How control protocol interacts with colour
Colour system and control protocol are separate BOM lines, but not every combination performs the same scheme. ON/OFF and TTL serve static or fixed-pattern work; DMX512 supports per-fixture addressing for dimming and scenes.
| Colour system | ON/OFF | TTL | DMX512 |
|---|---|---|---|
| Single-colour 1800–6500K | Static white | Fixed-pattern segments | Per-fixture dimming |
| RGB | Static or preset only | Fixed-pattern segments | Colour scenes |
| RGBW | Static or preset only | Fixed-pattern segments | Colour scenes plus white |
RGBW adds a dedicated white channel that needs its own control channel, which is why colour scenes belong in a DMX512 scheme. DMX512 control systems covers addressing, and DMX512 vs TTL vs ON/OFF for architectural lighting compares the protocols. The protocol is fixed at order stage; an ON/OFF unit cannot be re-addressed as DMX512 in the field. Pixel point lights documented at 36/64/100/144/256/400 points per square metre increase addressing and controller capacity needs, but density remains a layout decision made by the client’s designer.
Where colour sits in the documented range
The 2026 documentation set comprises 5 product catalogues with 98 model entries, plus a separate co-extruded flexible file of 53 items covering 48 neon flex strips, 2 wall-washer strips and 3 ultra-thin rigid bars. Colour options are confirmed per model rather than per family.
| Product family | Model entries | Colour note |
|---|---|---|
| Architectural linear lights | 10 | Single-colour 1800–6500K, RGB, RGBW confirmed per model |
| LED wall washers | 20 | Single-colour 1800–6500K, RGB, RGBW confirmed per model |
| LED floodlights | 29 | AC220V variants exist; colour confirmed per model |
| In-ground and underwater lights | 12 | IP68 applies to underwater items |
| Pixel point lights | 27 | 36/64/100/144/256/400 points per square metre |
Common lengths of 1000 / 500 / 260 mm, documented GD-WW power classes of 18/24 W, 24/36 W and 48/72 W, and beam angles of 10°, 15°, 30°, 45°, 60°, 10×30°, 10×45°, 10×60° and 20×60° are mechanical and optical lines that do not change with the colour system. How to choose a beam angle for facade lighting explains the optics, and how to read a photometric specification covers the data that accompanies them.
Choosing for a facade scheme
LED wall washers and pixel point lights are the two families most often mixed in a colour scheme, while facade lighting design describes how static and animated zones are laid out. How to specify linear LED light for building outlines covers the outline alternative.
| Scheme intent | Colour system | Control | Supply note |
|---|---|---|---|
| Fixed white facade | Single-colour 1800–6500K | ON/OFF or TTL | DC24V most low-voltage models |
| Seasonal colour scenes | RGB | DMX512 | DC24V most low-voltage models |
| Colour plus white | RGBW | DMX512 | DC24V most low-voltage models |
| Animated pixel facade | RGB or RGBW | DMX512 | DC24V most low-voltage models |
The compliance wording available is: “CE documentation available per model; scope confirmed per project. RoHS and IP test reports can be requested per model.” Catalogues state 50,000 hours for the source, a catalogue-stated figure, not a warranty commitment. GDXC is based in Guangming District, Shenzhen, Guangdong Province, China, prioritises the Middle East and Southeast Asia, and also covers Europe, North America, South America and Africa. Enquiries: chenliang@gdzm-led.com, +86 153 0264 9886, WhatsApp 8615302649886.
What we do not cover / Limits
This article compares colour systems for exterior architectural and landscape LED lighting only. It does not apply to indoor residential lighting or to road and tunnel main lighting, which are outside GDXC’s scope. GDXC does not sell LED chips, packages or bare light sources and does not publish client drawings. No exact white-temperature value beyond the documented 1800–6500K range, no colour rendering figure, no lumen output and no scene programming is provided here. The article does not cover submerged installations using non-IP68 models or AC220V mains floodlighting design. We do not promise unverified certifications, fixed lead times or published prices, and no warranty period is offered; the 50,000 hours figure is a catalogue-stated figure, not a warranty commitment. Final colour selection, control architecture, quotation and installation work must be confirmed by the client’s own engineering personnel.
This article describes general practice in outdoor architectural LED lighting. It is not a substitute for a project-specific review — beam angle, IP rating and control mode must be confirmed against the fixture schedule, the elevation and the site conditions.